Code CR3600DPM Informacje Techniczne Strona 51

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 72
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 50
10/29/2014
Page 51 of 72
© 2014 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg
Setting Name
Default
(Hex)
Comment
24F
Decoding Extras
0
This is a bitmask that enables additional decode data post-
processing.
Binary Dip Switch
Bit
Controls
Value
0
Send Code 39 start and stop delimiters
0: Disabled
1: Enabled
1
Remove Codabar start and stop
delimiters
0: Disabled
1: Enabled
2
Forces all decode data (excluding AIM
identifier and other prefix/suffix info) to
upper case
0: Disabled
1: Enabled
3
Forces all decode data (excluding AIM
identifier and other prefix/suffix info) to
lower case
0: Disabled
1: Enabled
4
Removes UPC-A check digit
0: Disabled
1: Enabled
5
Removes UPC-A number system digit
0: Disabled
1: Enabled
6
Removes UPC-E check digit
0: Disabled
1: Enabled
7
Removes UPC-E number system digit
0: Disabled
1: Enabled
8
Removes EAN/JAN-13 check digit
0: Disabled
1: Enabled
9
Removes EAN/JAN-8 check digit
0: Disabled
1: Enabled
10
Convert EAN-8 to EAN-13 (also see
register 04D)
0: Disabled
1: Enabled
11
Convert UPC-A to EAN-13 (also see
register 04D)
0: Disabled
1: Enabled
12
Convert Bookland EAN-13 to ISBN
0: Disabled
1: Enabled
13
Convert Bookland EAN-13 to ISSN
0: Disabled
1: Enabled
14
Send Tri-Optic Code 39 start and stop
delimiters
0: Disabled
1: Enabled
15
Remove GS1 Databar “()” characters, if
present
0: Disabled
1: Enabled
Przeglądanie stron 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 71 72

Komentarze do niniejszej Instrukcji

Brak uwag