SOFTWARE CONFIGURATION STRINGS
23
3
Command Syntax
1. Enter Service (Serial String Programming) Mode
$S<CR>
This command automatically sets the reader communication parameters to
115200,N,8,1.
2. Send Command
Command
<CR> $
Parameter Value
Where:
Command:
Description
HAXX
Interface Selection
AA
Enable All Symbologies
AD
Disable All Symbologies
R
Reset Reader
CXXXXXX
Write Single Configuration Item to RAM
Parameter:
XXXX
A 4-character ASCII string
See Serial Configuration Strings Table
Value:
XX
A 2-character Hex string
See Serial Configuration Strings Table
3. Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode
$Ar<CR>
This command automatically returns the reader to the programmed
communication parameters.