SOFTWARE CONFIGURATION STRINGS
35
3
CODE SELECTION
Description Parameter Value
Industrial 2 of 5
Industrial 2 of 5 Disable U2EN 00
Enable 01
Code Length Control Variable U2LC 00
Fixed 01
Set Length Length 1 (or Min Length) from 1 to 50 characters U2L1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters U2L2 v
Check Options
Check Calculation Disable U2CC 00
Enable 01
Check Tx Disable U2CT 00
Enable 01
Decoding Options
Minimum Reads One Read U2MR 01
Two Reads 02
Three Reads 03
Four Reads 04
Character Correlation Disable U2CO 00
Enable 01
Stitching Disable U2ST 00
Enable 01
v = Hex value from 00 to 32 representing the decimal number
CODE SELECTION
Description Parameter Value
Codabar
Codabar Disable CBEN 00
Enable 01
Code Length Control Variable CBLC 00
Fixed 01
Set Length Length 1 (or Min Length) from 3 to 50 characters CBL1 v
Length 2 (or Max Length) 0 or from 3 to 50 characters CBL2 v
ABC Codabar
ABC Codabar Disable CBAB 00
Enable 01
Concatenation Mode Static CBCM 00
Dynamic 01
Dynamic Concat. Timeout From 50 to 2550 ms CBDT t
Check Options
Check Calculation Disable CBCC 00
Enable AIM Standard Check 01
Enable Mod-10 Check 02
Check Tx Disable CBCT 00
Enable 01
Start/Stop Set ABCD/TN*E CBSC 00
ABCD/ABCD 01
abcd/tn*e 02
abcd/abcd 03
Start/Stop Tx Disable CBSS 00
Enable 01
Start/Stop Match Disable CBSM 00
Enable 01
v = Hex value from 00 or 03 to 32 representing the decimal number