TC1200 REFERENCE MANUAL
36
3
CODE SELECTION
Description Parameter Value
Decoding Options
Minimum Reads One Read CBMR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable CBDL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Character Correlation Disable CBCO 00
Enable 01
Interdigit Ratio Any ratio or 1 to 10 CBIR r
Quiet Zones Quiet Zone on One Side CBLO 01
Quiet Zones on Two Sides 02
Auto 03
Virtual Quiet Zones on Two Sides 04
Small Quiet Zones on Two Sides 05
Stitching Disable CBST 00
Enable 01
r = Hex value from 00 to 0A representing the decimal number of the interdigit space/module ratio (00 = any ratio)
CODE SELECTION
Description Parameter Value
Code 11
Code 11 Disable C1EN 00
Enable 01
Code Length Control Variable C1LC 00
Fixed 01
Set Length Length 1 (or Min Length) from 2 to 50 characters C1L1 v
Length 2 (or Max Length) 0 or from 2 to 50 characters C1L2 v
Check Options
Check Calculation Disable C1CC 00
Enable Check C 01
Enable Check K 02
Enable Check C and K 03
Check Tx Disable C1CT 00
Enable 01
Decoding Options
Minimum Reads One Read C1MR 01
Two Reads 02
Three Reads 03
Four Reads 04
Decoding Level Disable C1DL 00
Level 1 01
Level 2 02
Level 3 03
Level 4 04
Level 5 05
Character Correlation Disable C1CO 00
Enable 01
Interdigit Ratio 1 to 10 C1IR r
Stitching Disable C1ST 00
Enable 01
v = Hex value from 00 to 32 representing the decimal number
r = Hex value from
00 to 0A representing the decimal number of the interdigit space/module ratio (00 = any ratio)